Sign In | Join Free | My burrillandco.com
Home > Orifice Plate Flow Meter >

Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection

    Buy cheap Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection from wholesalers
     
    Buy cheap Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection from wholesalers
    • Buy cheap Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection from wholesalers
    • Buy cheap Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection from wholesalers
    • Buy cheap Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection from wholesalers

    Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection

    Ask Lasest Price
    Brand Name : vacorda
    Model Number : LG
    Supply Ability : 125 Piece/Pieces per Week
    Price : Negotiable
    Certification : CE/TUV/ISO9001/SGS
    • Product Details
    • Company Profile

    Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection

    Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection
    LG throttling gear is a primary device in a differential pressure flow measurement system, which consists of a throttle, a pressure-receiving device and a straight pipe section. Throttling device is divided into standard throttling device and non-standard throttling device, the one is coincident with IS05167 and GB/T2624 standard is the standard throttling device, the others are non-standard throttling deivce.
    When the pipe filled fluid flows through the throttling device in the pipe, according to the law of conservation of energy and the equation of flow continuity, the stream will form a local contraction at the throttle, thereby increasing the flow rate, static pressure reduction, static pressure difference ΔP(or named differential pressure) before and after the throttle. The greater the flow rate of the fluid, the greater the differential pressure generated before and after the throttle, and the amount of fluid flow is measured by measuring the differential pressure before and after the throttle.
    Standard throttling devices should normally be used whenever possible, and non-standard throttling devices can be used only when the fluid Reynolds number is small or contains impurities.
    Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection
    Technical Parameters
    Nominal diameter:DN15~1200(More than 1200 negotiated orders)
    Nominal pressure:≤42MPa
    Inaccuracy:±0.5%~±1.5%
    Installation method:Flange connection, Welded connection(or customized)
    Pressure method: Corner connection pressure (ring chamber or separate drilling), Flange pressure, Span pressure or else
    Straight pipe: Upstream5~10D,downstream2~5D

    Throttling device classification
    classificationPressure methodReference modelNominal diameter(mm)Nominal pressure(MPa)Diameter ratio
    Orifice plateSmall orifice plateCorner connection pressureLG-XH-40/2515~401.0~420.1~0.7
    Flange pressureLG-XF-40/2525~401.0~420.15~0.7
    Standard orificeCorner connection pressureLG-BH-320/10050~4001.0~420.23~0.8
    LG-BH-100/6550~2501.0~42
    LG-BH-63/5015~1501.0~42
    LG-BZ-16/600450~16000.6~2.5
    LG-BZ-10/50450~10000.6~1.6
    Flange pressureLG-BF-25/30050~7501.0~200.25~0.75
    LG-BZ-40/15050~4001.0~20
    Span pressureLG-BJ-63/15050~4001.0~63
    Built-in orificeLG-BFC-260/8050~4001.0~42
    Double orificeLG-SH-16/10025~4001.0~100.19~0.82
    1/4 round orificeLG-HH-160/10025~4001.0~260.32~0.71
    Conical inlet orifice plateLG-VH-16/10025~2001.0~4.00.12~0.32
    Round hole plateLG-QH-6/100050~16000.25~2.50.32~0.71
    LG-QH-25/60050~14000.25~2.5
    NozzleSmall nozzleLG-MH-40/3225~401.0~260.3~0.71
    Standard nozzleLG-PH-40/15050~6001.0~320.30~0.8
    LG-PH-63/20050~6001.0~32
    Long neck nozzleLG-CJ-260/8050~4001.0~320.22~0.8
    Venturi tubeVenturi nozzleLG-LT-16/15065~4000.6~2.50.32~0.78
    Classical venturiMachiningLG-WT-6/20050~6000.6~400.38~0.75
    Rough weldingLG-WT-6/1200200~20000.6~2.50.38~0.73


    Small orifice plate, Small nozzle Reference size table

    Pressure LevelSizeDN15DN25DN32DN40
    PN25D95115135145
    L126128143149
    PN40D95115135148
    L126147148148
    PN63D105135150165
    L126152159177
    PN100D95135150165
    L126155162178

    Note: The length L is based on the actual size, and the dimensions in the table are for reference only.
    Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection
    Company Profile and Certificate
    Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type ConnectionCompressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection













    Product Tags:

    orifice flow meter

      

    oxygen flow meter

      
    Quality Compressed Air Orifice Plate Flow Meter With Flange Or Wafer Type Connection for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sichuan Vacorda Instruments Manufacturing Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)